Offline Oil Health Condition

  • The only instant onsite grease/oil ferrous analyzer globaly

    Fast measurement 2 seconds

    Sample size: 2mg Grease/2ml Oil

    Touchscreen: 5.5inch

    Battery life: >5 hours

    Sensitivity: lmg/L (PPM)

    Detection repeatability: <l % RSD

    Calibration Standard: 0mg/L & I 050mg/L

    Complys: ASTM D8120

    Test range: 0-5500 mg/L (PPM)

    Power: AC 100-240V, 50/60Hz

    Temperature range: 0-50°C

    Dimension & Weight: 250x218xl33(mm); 2.7KG

    Consumable: 2ml oil tube and grease h1be

    Standard package: Standard calibration sample of 0mg/L and 1050mg/L l00pcs oil/grease tube, power adapter, USB drive and user manual.

  • WPF6 Quick Oil Analyzer

    Oil samples can be tested instantly with printed test result. Consumable not required

    Easy to maintain.

    Convenient to use,

    5-inch touch screen display.

    Rechargeable battery - 4 hours operation

    Inbuild heating device

    Instant printout of test result.

    Equipped with industrial carrycase.

    Test time: 5 Seconds

    Oil sample volume: Around 10ml

    Dimension &Weight: 387x289x104 mm; 3KG

    Testing Parameters:

    Viscosity: l~IOO0cSt, Accuracy: ±4~9%

    Density: 600~1250 kg/m', Accuracy: ±3%

    Oil quality (Dielectric constant): 1~6, Accuracy: ±6%

    Temperature: O~l 10°C (Accuracy: ±0.3°C)

    Water Activity (Humidity/Saturation): 0~1 aW, Accuracy: ±0.02 aW

    Moisture content (dissolved water): 0~2000PPM, Accuracy: ±10% or

    10 PPM, whichever the larger (default calibrated with hydrauUc oil #68)

  • WJS-150 Portable Particle Counter

    WJS-150 Portable Particle Counter works on principle of light extinction (or light-blockage) and is used to detect the size and quantity of solid particles in liquid.

    Light source: Semiconductor laser

    Particle size range: 1um~lO0um

    Sensitivity: 1um (ISO4402) or 4um (C) (ISO 11171)

    Particle counting accuracy: ±10% or ±0.5 level

    Test Repeatability: RSD<5%

    Off-line viscosity detection: :'Sl00cSt (With a pressure device to 400cSt)

    Detection channel: 8 Channels

    Calibration standard: ISO4402 & ISO11171

    Test standards: ISO4406, NAS1638, TOCT17216, SAS4059D, SAE749D and user define particle size;

    Sampling volume: 10ml, sampling volume accuracy: <±3%

    Detection velocity: 0~60m L/min

    Cleaning velocity: 0-60m L/min

    On-line detection pressure: 0.1 -0.6MPa (With a pressure device to 41 Mpa)

    Liquid temperature: 0-60°C

    Dimension & Weight: 268x246x148mm; 6KG

    Additional accessories (optional): WRT-T Pressure Sampling device, Ultrasonic cleaner, Sample Shaker.

  • WYTD-3 Ferrous Debris Monitor (PQ)

    TI1e WYTD-3 FeITous Debris Monitor can measure the PQ index (total wear debris content) of oil/grease samples, the wear condition of the equipment can be detected and monitor the abn01mal wear at the eai-ly stage for predictive equipment maintenance.

    Display: 5. 6-inch Touchscreen (640*480)

    Measuring Range: 0 -15000PQ

    Accuracy: 200PQ-15000PQ <±1%; 0PQ-200PQ<±3 PQ;

    Detect Wear Debris:>1um (Ferromagnetic wear particles)

    Test time on each sample: 11 second for one time measurement

    Package include: Standard calibration sample of 0PQ and 750PQ, Validation Sample: 100~120PQ, lO0pcs 5ml oil cup, power adapter, RS232 cable,user manual.

    Power: AC 100V-240V 50Hz/60Hz

    Power Dissipation: < l5W

    USB P011: Software update/Test records exp01t

    RS232 port: To connect with computer through ModBus communication

    Instrument Dimension and Weight: 402x266x186mm; 5.5kg

    Operating environment: <80%RH; 15°C-30°C

    Consumable: 5ml Plastic Sample cup for Oils & Greases

  • Online Oil Monitoring Solution
    Gear Oil Monitoring Systen1-Comprehensive

    Advantages: • Easy installation • Comprehensive monitoring range • Remote diagnosis system

    WYSl-718 Analyses 8 parameters simultaneously:

    1. Oil Density
    2. Dynamic Viscosity
    3. Kinetic Viscosity
    4. Temperature
    5. Oil Quality - Dielectric Constant
    6. Moisture Content in Oil (ppm)
    7. Water activity
    8. Oil Wear Debris

    (Fe paiticles >40~99µm,100~199µm, 200~299µm, 300~399µm, >=400µm) (Non-Fe particles>150~199µm, 200-299µm, 300~399µm, 400~499µm, >=500µm)

  • Gear Oil Monitoring System

    WNS2-718 Hydraulic/Turbine/Transformer Oil System Comprehensive

    1. Oil Density
    2. Dynamic Viscosity
    3. Kinetic Viscosity
    4. Temperature
    5. Oil Quality - Dielectric Constant
    6. Moisture Content in Oil (ppm)
    7. Water activity
    8. Oil Particle Count (NAS Value or ISO- User can configme) Particle size: 1 2, 5, 10, 15, 25, 50 l00µm

    Online oil monitoring system can be customized to your required parameters

  • WFJ4 Quick Particle Counter-Analyzer

    On-site quick oil analysis - Particle counting and humidity measurement

    Output 8 channels particle counting under ISO 4406, AS1638, SAE AS 4059F

    Support to manually calibrate on different viscosity oil sample measurement

    Industrial carrycase mounted

    Light source: Semiconductor laser

    Particle size range: lum~l00 um

    Sensitivity: lmn (IS04402) or 4 umm(C) (ISOl 1171)

    Pa1ticle cmmting accuracy: ±20% or ± 1 level

    Test Repeatability: RSD<5%

    Off-line viscosity detection: <=S220cSt (With a pressure device can up to 400cSt)

    Detection channel: 8 Channels

    Calibration standard: ISO4402 & ISO11171

    Test standards: ISO4406, NAS1638, SAE AS4059F

    On-line detection pressure: 0.l~0.6MPa (With a pressure device can up to 41 Mpa)

    Humidity measurement: 1-100% RH- ±3%

    On-line detection pressure: 0.l~0.6MPa (With a pressure device can up to 41 Mpa)

    Liquid temperature: 0~80°C

    Dimension & Weight: 273x200xl34mm; 5 KG

  • WOT Quick Co1nprehensive Analyzer

    WOT Quick Comprehensive Oil Analyzer acts as a mobile oil analysis lab & can instantly measure oil quality parameters plus AS value or Wear Debris pollution.

    Temperature: 0~ 120°C (Accuracy: ±0.3°C)

    Density: 600~1250 kg/m3 (Accuracy: ±3%)

    Viscosity(cSt): 40°C: 1-l0OOCst; Accuracy: ±5~8%

    Water activity (aW) /Humidity: 0~ 1 aW (Accuracy: ±0.02 aW (0~0.6) and ±0.03aW(0.6~0.9) and ±0.04aW(0.9~1)

    Oil Quality (Dielectric constant): 1~6 (Accuracy: ±3%)

    Optional Partical Counter:

    Contaminants and pollution degree: NAS1638, ISO4406 and SAE AS4059F standard

    Particle size range: 1-lOOum (oil viscosity up to 320eSt), 8 channel

    Accuracy: ± 1 pollution level

    Optional Wear Debris:

    Fe pa1ticles >40~99µm,100-199µm, 200~299µm, 300~399µm, >=400µm
    Non-Fe particles>150-199µm, 200~299µm, 300-399µm, 400~499µm, > 500µm

  • Viscosity/Moisture Pen for Condition Monitoring VP01NP02

    Measurement


    • Viscosity :
    • Density :
    • Temperature :
    • Water activity (Humidity/Saturation) :
    • Moisture content (dissolved water) :
    • 1-l000cSt (Accuracy: ±5%)
    • 600-1250 kg/m3 (Accuracy: ±5kg/m3)
    • -40 ~ 120°C (Accuracy: ±0.5°C)
    • 0 ~ 1 aW (Accuracy: ±0.03aw)
    • 0 ~ 5000PPM (Accuracy: ± 10% OR 10 PPM, whichever the larger)

    Specifications


    • Liquid temperature :
    • Working temperature :
    • Temperature :
    • Power Supply IP rate :
    • Charging :
    • Material :
    • Dimension :
    • Weight :
    • -40°C ~ 120°c
    • -40°C ~ 105°C
    • 4 to 5 hours continuous usage
    • IP66
    • TypeC
    • stainless steel 316
    • Length 152.4mm x φ34mm
    • 0.442KG

    Application:


    Commonly used mineral oil, synthetic and semi-synthetic lubricating oil, hydraulic oil, transformer oil and other lubricating oils.

    Structure drawing:


    VPOl : Viscosity, Density and Temperature